(VAMS®) aims to absorb a fixed volume of blood or other fluid (10 or 20 μL) using the Mitra® (Neoteryx) device (Spooner et al., 2015; Protti et al., 2019). Although some aspects still need to be investigated in depth (Kip et al., 2017), VAMS® may be a viable alternative to DBS. It simplifies sample collection and storage, and may allow sample collection in a patient's home (Kok & Fillet, 2018). The HemaXisTM DB 10 (DBS System SA) uses microfluidics to provide 10 μL whole blood from a reservoir onto a DBS card (Leuthold et al., 2015; Verplaetse & Henion, 2016). The HemaXisTM DX promises to produce plasma or serum without the use of a centrifuge, filtration membrane, or pump and with no haemolysis. The resulting sample can be stored in dried or liquid format. The Noviplex™ Plasma Prep Card gives a fixed volume of plasma from a reservoir of whole blood (Heussner et al., 2017).

       2.2.4 Urine

      Different urine specimens, e.g. random, early morning, end-of-shift, 24-hour (the total urine voided over a day), may be collected in the course of metabolic or other studies. In metabolic studies, it is important to note the time of the beginning and end of the collection period so that the rate of urine production can be calculated. A random urine sample is usually a midstream specimen. A preservative, for example 2 mol L–1 hydrochloric acid to prevent microbial growth and to stabilize phenols, may be added. Fresh urine is yellow/yellow-green in colour, but on storage in acidic solution the colour changes to yellow/brown and even to dark brown because of the oxidation of urobilinogen to urobilin. Crystals, particularly of uric acid and calcium oxalate, may form causing turbidity.

      When random, early morning, or end-of-shift specimens are collected it is common practice to relate certain analytical results to a ‘fixed’ urinary constituent such as creatinine, which is considered to be excreted at a relatively constant rate in normal subjects. However, because creatinine is derived from creatine, there are situations such as muscle wasting, excessive exercise, or in bodybuilders dosing with creatine, when this is not strictly true. Note that many clinical chemistry laboratories report creatinine in mmol L–1 (1 mmol L–1 = 113 mg L–1).

      The concentrations of many drugs and metabolites, and of some endogenous constituents, will remain the same in acidified urine for over a week at room temperature, and for up to a month at 2–8 °C. Unacidified urine undergoes microbiological attack and many changes occur, including the complete loss of amino acids. For long term storage acidified urine can be stored at –20 °C, but it may be necessary to centrifuge the sample to remove any precipitate formed during storage prior to any analysis. Dried urine spots may also be produced in an analogous manner to dried blood spots.

       2.2.5 Stomach contents

      This specimen encompasses vomit, gastric aspirate, and gastric lavage fluid as well as the contents of the stomach at post-mortem. The nature of this sample can be very variable and additional procedures such as homogenization followed by filtration and/or centrifugation may be required to produce a sample amenable to analysis. Sometimes tablet residues may be apparent, study of which which might help identify the drug ingested.

       2.2.6 Faeces

       2.2.7 Tissues

      Histology specimens are usually collected into a preservative such as formalin (37 % w/v) aqueous formaldehyde solution). Such pre-treatment must be borne in mind if toxicological analyses are requested subsequently. Samples of tissue obtained post-mortem are normally kept at 2–8 °C prior to analysis.

      If poisoning is suspected, a 10 mL blood sample (lithium heparin or EDTA tube) should be taken from an adult (proportionally less from a young child) as soon as possible. In addition, 2 mL of blood should be collected in a fluoride/oxalate tube if ethanol is suspected. Note that tubes of this type for clinical use contain only ca. 0.1 % w/v fluoride (Table 2.3), whereas ca. 2 % w/v fluoride (40 mg sodium fluoride per 2 mL blood) is needed to inhibit fully microbial action in such specimens. Addition of fluoride may also help protect other labile drugs such as clonazepam, cocaine, and nitrazepam from degradation. If possible, the retention of an unpreserved blood sample is also advisable.

Sample Notesa
Whole blood 10 mL (lithium heparin or EDTA tube – use fluoride/oxalate if ethanol suspected; plastic tube if paraquat suspected; glass or plastic tube with minimal headspace if carbon monoxide or other volatiles suspected)
or Plasma/serum 5 mL (send whole blood if volatiles, metals, and some other compounds suspected – see above)
Urineb 20–50 mL (plain bottle, no preservativec)
Gastric contentsd 25–50 mL (plain bottle, no preservative)
Scene residuese As appropriate

      aSmaller volumes may often be acceptable, for example in the case of young children

      bNormally the only sample that is required for substance misuse screening

      cSodium fluoride (2 % w/v) should be added if ethanol is suspected and blood is not available

      dIncludes vomit, gastric lavage (SWO, first sample), etc.

      eTablet bottles, drinks containers, aerosol canisters, etc. – pack entirely separately from biological samples, especially if poisoning with volatiles is a possibility