Small Animal Laparoscopy and Thoracoscopy. Группа авторов

Чтение книги онлайн.

Читать онлайн книгу Small Animal Laparoscopy and Thoracoscopy - Группа авторов страница 47

Small Animal Laparoscopy and Thoracoscopy - Группа авторов

Скачать книгу

Bailey, J.E., Pablo, L.S. (1998) Anesthetic and physiologic considerations for veterinary endosurgery. In: Freeman, L.J. (ed.) Veterinary Endosurgery. Mosby, St. Louis, pp. 24–43.

      54 54. Connor, S. (2013) Checklists are not only for the operating room. ANZ J Surg 83 (10), 704–705.

      55 55. Freeman, L.J. (1999) Operation room setup, equipment and instrumentation. In: Freeman, L.J. (ed.) Veterinary Endosurgery. Mosby, St. Louis, pp. 3–23.

      56 56. Mayhew, P.D. (2009) Advanced laparoscopic procedures in dogs and cats. Vet Clin North Am Small Anim Pract 3, 925–939.

      57 57. Mayhew, P.D., Freeman, L.J., Kwan et al. (2009) Prospective comparison of post‐operative wound infection rates after minimally invasive versus open surgery. Proceedings of the Veterinary Endoscopy Society Annual Meeting, Vancouver, British Columbia, March 7.

      58 58. Skinner, A.C. (1994) Minimally invasive surgery. BMJ 308 (6927), 532‐533.

      59 59. Twedt, D.C., Monnet, E. (2005) Laparoscopy: technique and clinical experience. In: McCarthy, T.C. (ed.) Veterinary Endoscopy for the Small Animal Practitioner. Elsevier Saunders, St. Louis, pp. 357–385.

      60 60. Freeman, L.J., Pader, K. (2012) NOTES applications in veterinary medicine. In: Kalloo, A.N., Marescaux, J., Zorron, R. (eds.) Natural Orifice Translumenal Endoscopic Surgery: Textbook and Video Atlas, Wiley, Hoboken, NJ, pp. 215‐231.

      61 61. Guinet, A., Chaabane, S. (2003) Operating theatre planning. Int J Prod Econom 85 (1), 69–81.

      62 62. Kenyon, T.A.G., Lenker, M.P., Bax et al. (1997) Cost and benefit of the trained laparoscopic team. Surg Endosc 11 (8), 812–814.

      63 63. Meijer, D.W. (2003) Safety of the laparoscopy setup. Minim Invasive Ther Allied Technol 12 (3‐4), 125–128.

      64 64. Quandt, J.E. (1999) Anesthetic considerations for laser, laparoscopy, and thoracoscopy procedures. Clin Tech Small Anim Pract 14, 50–55.

      65 65. Richter, K.P. (2001) Laparoscopy in dogs and cats. Vet Clin North Am Small Anim Pract 31, 707–727.

      66 66. Weisse, C., Mayhew, P. (2012) Minimally invasive operating room equipment. In: Tobias, K.M., Johnston, S.A. (eds.) Veterinary Surgery Small Animal. Elsevier, Saunders, Philadelphia, pp. 291–303.

      67 67. Cook, R.I., Woods, D.D. (1996) Special section: adapting to new technology in the operating room. human factors. J Hum Factors Ergonon Soc 38 (4), 593–613.

      68 68. Healey, A.N., Sevdalis, N., Vincent, C.A. (2006) Measuring intra‐operative interference from distraction and interruption observed in the operating theatre. Ergonomics 49 (5‐6), 589–604.

      69 69. Lenoir, C., Steinbrecher, H. (2010) Ergonomics, surgeon comfort, and theater checklists in pediatric laparoscopy. J Laparoendosc Adv Surg Tech A 20 (3), 281‐291.

      70 70. Maclean, A.R., Dixon, E., Ball, C.G. (2013) Effect of noise on auditory processing in the operating room. J Am Coll Surg 216 (5), 933–938.

      71 71. Nguyen, N.T., Ho, H.S., Smith, W.D., et al. (2001) An ergonomic evaluation of surgeons’ axial skeletal and upper extremity movements during laparoscopic and open surgery. Am J Surg 182 (6), 720–724.

      72 72. Van Det, M.J., Meijerink, W.J.H.J., Hoff, C., et al. (2009) Optimal ergonomics for laparoscopic surgery in minimally invasive surgery suites: a review and guidelines. Surg Endosc 23 (6), 1279–1285.

      73 73. Alarcon, A., Berguer, R. (1996) A comparison of operating room crowding between open and laparoscopic operations. Surg Endosc 10 (9), 916–919.

      74 74. Cardoen, B., Demeulemeester, E., Beliën, J. (2010) Operating room planning and scheduling: a literature review. Eur J Oper Res 201 (3), 921–932.

      75 75. Farrokhi, F.R., Gunther, M., Williams, B., et al. (2013) Application of lean methodology for improved quality and efficiency in operating room instrument availability. J Healthc Qual Sep 24. doi: 10.1111/jhq.12053. [Epub ahead of print].

      76 76. Hsiao, K.C., Machaidze, Z., Pattaras, J.G. (2004) Time management in the operating room: an analysis of the dedicated minimally invasive surgery suite. JSLS 8 (4), 300–303.

      77 77. Kazemier, G., Van Veen‐Berkx, E. (2013) Comment on “Identification and use of operating room efficiency indicators: the problem of definition.” Can J Surg 56 (5), E103–E104.

      78 78. Kenyon, T.A.G., Urbach, D.R., Speer, J.B., et al. (2001) Dedicated minimally invasive surgery suites increase operating room efficiency. Surg Endosc 15 (10), 1140–1143.

      79 79. Low, D., Walker, I., Heitmiller, E.S., et al. (2012) Implementing checklists in the operating room. Paediatr Anaesth 22 (10), 1025–1031.

      80 80. Papaconstantinou, H.T., Smythe, W.R., Reznik, S.I., et al. (2013) Surgical safety checklist and operating room efficiency: results from a large multispecialty tertiary care hospital. Am J Surg 206 (6), 853–860.

      81 81. Gould, S.W.T., Darzi, A. (1997) The interventional magnetic resonance unit: the minimal access operating theatre of the future? Br J Radiol 70 (Suppl.), S89–S97.

      82 82. Herron, D.M., Gagner, M., Kenyon, T.L., et al. (2001) The minimally invasive surgical suite enters the 21st century. Surg Endosc 15 (4), 415–422.

      83 83. Santambrogio, R., Montorsi, M., Bianchi, P., et al. (1999) Intraoperative ultrasound during thoracoscopic procedures for solitary pulmonary nodules. Ann Thorac Surg 68 (1), 218–222.

      84 84. Varu, V.N., Greenberg, J.I., Lee, J.T. (2013) Improved efficiency and safety for EVAR with utilization of a hybrid room. Eur J Vasc Endovasc Surg 46 (6), 675–679.

      85 85. Weisse, C.W., Berent, A.C., Todd, K.L., et al. (2008) Potential applications of interventional radiology in veterinary medicine. J Am Vet Med Assoc 233, 1564–1574.

      86 86. Yamada, K., Morimoto, M., Kishimoto, M., et al. (2007) Virtual endoscopy of dogs using multi‐detector row CT. Vet Radiol Ultrasound 48 (4), 318–322.

       Elizabeth A. Swanson

      Key Points

       Endoscopic instruments are modified basic surgical instruments and include forceps, scissors, tissue retractors, and needle holders.

       Types of forceps include grasping, dissection, and biopsy.

       The working end has a single‐ or double‐action mechanism.

       For most surgical application in small animals, 5 mm instruments are adequate.

       Endoscopic instrument packs should include traditional open surgical instruments for securing of drapes and initial port entry and possible for conversion to open surgery.

      Endoscopic surgical instruments are designed to have the same functions as traditional open surgical instruments and thus are simply modifications of the basic instrument categories, including forceps (grasping, dissecting, and biopsy), scissors, tissue retractors, and needle holders. Several

Скачать книгу