true benefit of drainage. “Drains provide a false sense of security and re‐assurance; we have all seen the moribund post‐operative patient with an abdomen crying to be reexplored while his surgeon strongly denies any possibility of intraperitoneal catastrophe because the tiny drains he inserted in each abdominal quadrant are ‘dry' and nonproductive. We cannot produce high‐level evidence to support our aversion to drains, but the generations of surgeons who used drains for many years also never succeeded in proving their advantage” (Schein 2002).

      Open drainage has been historically used mostly during the treatment of generalized septic peritonitis with either presence of lot of foreign materials in the pleural space or bile. Bile salts are very caustic and potentiate the virulence of bacteria. Open drainage of the peritoneal cavity is rarely recommended in human medicine for the treatment of peritonitis (Schein 2002).

      Drainage of the peritoneal space should also reduce the risk of compartment syndrome resulting from the accumulation of abdominal effusion in the close space of the abdominal cavity. It might be the major benefit of the drainage of the peritoneal space (Schein et al. 1995; Schein 2002).

      Drainage of a uroabdomen due to a ruptured urethra or bladder is an important component of the stabilization for the patient before abdominal surgery. Drainage of the urine present in the abdominal cavity is an important component of the treatment of hyperkalemia present with a uroabdomen. After placement of a percutaneous drain diuresis can be started to help lower the potassium level.

      Drainage of the peritoneal cavity can be achieved with either a closed suction drain, a negative pressure drainage system, or an open abdomen (Salisbury and Hosgood 1989; Hosgood 1990; Hosgood et al. 1991; Ludwig et al. 1997; Staatz et al. 2002; Buote and Havig 2012; Adams et al. 2014). Drains can be placed percutaneously with a local block or surgically during a laparotomy.

      5.2.1 Percutaneous Placement of an Abdominal Drain

Photo of a simple red rubber feeding tube.

      5.2.1.1 Passive Drain

      The patient is placed in right lateral recumbency. After surgically preparing the left caudal abdominal wall, a local block with bupivacaine is performed in the skin and the abdominal wall where the drain is going to be inserted. A bolus of fentanyl can be given to the patient also. The puncture in the abdominal wall is 2–3 cm cranial to the skin incision. A small skin incision is performed with a #15 blade where the local block was performed. A 2–3 cm subcutaneous tunnel is created with a curved Carmalt forceps in a cranial direction toward the local block in the abdominal wall. The tip of the red rubber feeding tube is then grabbed by the curved Carmalt and advanced in the tunnel. The abdominal wall is then punctured with the Carmalt and the red rubber feeding tube. The tube is then advanced in the abdominal cavity.

      The red rubber feeding tube is then secured to the skin with a Chinese finger trap with 2‐0 nylon. The tube is then connected to a passive collection system.

      If a fenestrated Penrose drain is placed around the red rubber feeding tube it is inserted in a similar fashion than the simple red rubber feeding tube.

      5.2.1.2 Closed Suction Drain

      The patient is prepared as described above for the placement of a passive drain.

      Usually a Seldinger technique is used to place a closed suction drain percutaneously. An 18G catheter is tunneled under the skin into the abdominal cavity. A wire is then advanced in the catheter into the abdominal cavity. The 18G catheter is then removed and the closed suction drain is advanced over the wire into the abdominal cavity.

      The drain is secured to the skin with a Chinese finger trap with 2‐0 Nylon. The drain is then connected to a suction device and a reservoir. The device generates a negative pressure close to 10 mmHg. Usually the reservoir can be 100–400 ml depending on the size of the animal and the amount of effusion that is expected to be produced.

      5.2.2 Surgical Placement of a Closed Suction Drain

      According to the dynamic of fluids in the abdominal cavity, abdominal effusion moves from the caudal to cranial toward the diaphragm (Hosgood et al. 1989). Therefore drains need to be placed in the cranial part of the abdominal cavity between the liver lobes and the diaphragm. In this position the drain should be more efficient for collecting in the abdominal cavity and also it should keep the drain away from the omentum.

Photo displaying three various flat silicon drains. Photo displaying a suction device with a reservoir connected to a flat silicon drain.

      The drain needs to be inspected daily to reduce the risk of contamination and ascending infection.

      5.2.3 Open Abdomen

      An open abdomen allows passive drainage of the abdominal effusion in a sterile bandage applied over the midline incision of the laparotomy (Staatz et al. 2002; D'Hondt et al. 2007; Madback and Dangleben 2015). This technique allows daily lavage of the peritoneal space while the bandage is changed (Staatz et al. 2002; D'Hondt et al. 2007). It can also be associated to a vacuum‐assisted bandage to actively