18 1551.1 963.8 575 205.7964 19.078 0.0909 0.0063 19 1520.0 963.8 550 192.0793 18.7495 0.0848 0.0065 20 1505.6 963.8 550 187.6298 18.4184 0.0829 0.0063 21 1505.6 963.8 550 187.6298 18.4184 0.0829 0.0063 22 1520.0 963.8 550 192.0793 18.7495 0.0848 0.0065 23 1435.6 963.8 525 166.2875 16.3785 0.0735 0.0055 24 1219.6 963.8 425 110.9501 10.774 0.0491 0.0035 Graph depicts the variation of VDI before and after placement of DGs to the 69-bus distribution network. Graph depicts the voltage profile of 69-bus distribution network before and after placement of DGs for 15th load hour.

      In this current book chapter, optimum placement of RDGs (such as biomass DG and solar PV) and shunt capacitors is studied with an objective to minimize a multi-objective function. The multi-objective function includes active power loss reduction, improvement of voltage profile, and reduction of effective annual installation cost. To optimize the size and the location of the DGs simultaneously, a new optimization algorithm named mixed discrete SPBO algorithm is used which is able to take care both the continuous and the discrete variables.

      The proposed method has been coded in MATLAB software and compared with four different optimization methods, such as PSO, TLBO, CS and SOS, available in the literature. For the comparison purpose, the CEC-2005 benchmark functions have been considered, and the comparison has been made from the point of view of best FF, worst FF, mean, standard deviation and rank. For almost all benchmark functions, the proposed SPBO method has been provided the better results. Therefore, it can be concluded that the proposed method is superior than the other four methods considered in this book chapter.

      The multi-objective RDGs and capacitors sizing and placement study has been carried out considering the variable load demand of a day. After the placement of biomass DG, solar PV, and shunt capacitors to the 33-bus and 69-bus distribution network using mixed discrete SPBO algorithm, it may be noticed that the active power loss reduction for all the load demands of the day and for both the considered distribution networks is quite significant. Significant reduction of VDI may also be noticed after the placement of DGs to both the distribution networks and for all the different load hours. The effective annual installation cost is also found to be less for both the distribution networks.

      From the study, it may be concluded that the proper placement of biomass DG, solar PV, and shunt capacitors may lead to a significant reduction in active power loss, VDI, as well as effective annual installation cost, for both the considered 33-bus and 69-bus distribution networks. It is also worth mentioning that the mixed discrete version of SPBO is capable to optimize the sizes and locations of the DGs simultaneously in order to achieve the desired objective. It can also be concluded that the mixed discrete SPBO is very much capable to optimize both continuous and discrete variables simultaneously.

      1. Acharya N., Mahat P., and Mithulananthan N. (2006) An analytical approach for DG allocation in primary distribution network. Int. J. Electr. Power Energy Syst. 28(10):669-678.

      2. Gözel T., and Hocaoglu M.H. (2009) An analytical method for the sizing and sitting of distributed generators in radial systems. Electr. Power Syst. Res. 79(6):912-918.

      3. Wang C., and Nehrir M.H. (2004) Analytical approaches for optimal placement of distributed generation sources in power system. IEEE Trans. Power Syst.19(4):2068-2076.

      4. Hung D.Q., Mithulananthan N, and Bansal R. C. (2010) Analytical expressions for DG allocation in primary distribution networks. IEEE Trans. Energy Convers.25(3):814-820.

      5. Aman M.M., Jasmon J., Mokhlis H., and Bakar A. (2012) Optimal placement and sizing of a DG based on new power stability index and line losses. Int. J. Electr. Power Energy Syst. 43(1):1296-1304.

      6. Celli G.,Ghiani E., Mocci S., and Pilo F. (2005) A multi-objective evolutionary algorithm for the sizing and sitting of distributed generation. IEEE Trans. Power Syst. 20 (2): 750-757.

      7. Falaghi H., and Haghifam M.R. (2007) ACO based algorithm for distributed generation sources allocation and sizing in distribution systems. In: Proc. IEEE Power Tech.: 555-560.

      8. Al Abri R.S., El-Saadany E.F., and Atwa Y.M. (2013) Optimal placement and sizing method to improve the voltage stability margin in a distribution system using distributed generation. IEEE Trans. Power Syst. 28(1): 326–334.

      9. Borges C.L.T., and Falcao D.M. (2006) Optimal distributed generation

Скачать книгу